A summary of Thermal Bypass due to Airflow, RDH Building Science Inc., November 2026
RDH Building Science reviewed six decades of published testing on airflow-induced thermal bypass and found reductions in effective thermal performance ranging from a few percent to more than 100 percent, depending on insulation type, detailing, and installation quality. This page summarizes what the paper measured and what it recommends.
This page summarizes the findings. The full paper is available to download at the end of this article.
What does the research cover?
The paper reviews airflow-induced thermal bypass in exterior wall assemblies: natural convection within and around insulation, and wind washing driven by air moving through, behind, or around it. It draws on physical testing and field measurement published between 1966 and 2018 and translates the findings into practice recommendations.
The central point is that measured thermal performance depends on more than the nominal R-value of the insulation. It depends on whether heat can bypass the insulation layer altogether.
These mechanisms can occur even where the primary air barrier is well designed and well-constructed. Exterior continuous insulation typically sits outboard of the air barrier, so air moving within the rainscreen cavity, behind insulation boards, or through air-permeable insulation can bypass the insulation independently of any air leakage through the building.
What did the testing show for gaps between insulation boards?
In testing summarized by the paper, a 1/4 inch gap between adjacent insulation boards increased heat flow by roughly 30 percent, with no wind, driven by temperature difference alone, in a wall with a 1 1/2 inch rainscreen cavity and a 1/4 inch cavity behind the insulation. Widening the cavity behind the insulation to 3/8 inch caused the same gap to more than double heat flow.
The finding that matters for specification is the interaction. The cavity behind the insulation multiplies the effect of the gap in front of it.
The research conclusion is to minimize gaps between boards and press the insulation tight, within an eighth of an inch, to the backup wall.
Source: Physical testing of heat flow through air-impermeable insulation with board-joint gaps under natural convection, reported by Lecompte, Insulation Materials, Testing, and Applications, ASTM STP 1030, 1990. Summarized in Haaland and Straube, Thermal Bypass due to Airflow, RDH Building Science Inc., November 2026, sections 2.3 and 3.2.
What did the research find about cavities behind the insulation?
Gaps of about 1/4 inch can easily form behind rigid insulation from ordinary substrate irregularity and the cladding attachment itself. A cavity behind the insulation multiplies the effect of any gap between boards.
The paper lists the irregularities that commonly prevent rigid boards from bearing tightly against the backup wall:
- Laps in membranes
- Cladding attachment flanges
- Localized fastener heads
- Transitions between materials
- Misaligned floor edges and sheathing offsets
Suggested mitigations include substrate preparation, more frequent insulation fastening, furring or retention components that hold the insulation tight to the backup wall, more conformable insulation materials, and joint treatments that reduce airflow between boards.
What did the research find at cladding attachments?
Gaps around some clip geometries can reach about 1/4 inch. Combined with a cavity of similar size behind the insulation, heat flow can increase by more than 30 percent. The paper notes that thermal bridging through attachment components is commonly considered in effective R-value calculations, while the gaps around and behind them are often not explicitly accounted for.
Among the practices the paper recommends for gaps at cladding attachment is a combined clip and insulation system. The SMARTci® system takes that approach with the GreenGirt CMH™ Z-girt: custom-profiled insulation panels are manufactured to mate with the Z-girt, so the fit around the attachment does not depend on how carefully each board was cut on site.
Source: Haaland and Straube, Thermal Bypass due to Airflow, RDH Building Science Inc., November 2026, section 3.3.
Is wind washing a real concern for exterior continuous insulation?
Generally, no, where the insulation is well installed. The paper reports that the thermal impact of wind washing is limited to less than a few percent for fibrous insulation above 1.25 pcf installed in substantial contact with the air barrier and without gaps.
This is worth stating plainly, because it narrows the problem rather than widening it. Wind washing is a serious concern for low-density batt insulation exposed directly to wind-driven air in framed cavities without an exterior air barrier. It is not, on its own, a significant concern for the exterior insulation products commonly used in construction when they are well installed.
The broader concern the paper returns to is thermal bypass caused by airflow through, around, or behind insulation where gaps, discontinuities, or uncontrolled air leakage paths are present.
What does the research recommend?
Treat exterior continuous insulation as an installed system rather than only as a material layer with a nominal R-value. The paper concludes that appropriate design, coordinated cladding attachment detailing, suitable product selection, tight-fitting installation, joint treatment, and construction-stage review can reduce or eliminate the risk of airflow-induced thermal bypass in most practical wall assemblies.
The paper summarizes common defects and the practices that mitigate them:
| Defect | Recommended practice |
|---|---|
| Gaps between continuous board insulation | Seal gaps over 1/8 inch using joint designs, tapes, or sealants; offset board joints in multi-layer installations; specify shiplap or tongue-and-groove board joints; oversize compressible insulation by about 5 percent to allow a tight fit; precisely cut rigid foam |
| Gaps at cladding attachment | Specify a combined clip and insulation system, such as a clip with matching profiled foam; match the insulation to the cladding attachment solution; use an insulative filler where a gap remains |
| Gaps behind continuous board insulation | Press insulation tight to the substrate; use more conformable insulation |
| Very low density, high air permeance insulation | Select insulation products with higher air resistance; protect relatively air-permeable insulation; avoid rainscreen air gaps much greater than 1 inch; avoid combining air-permeable insulation with open-jointed cladding without additional mitigation |
Regular construction-stage inspection is recommended alongside these measures, since the defects involved are not uncommon.
Who conducted the research?
Daniel Haaland, M.A.Sc., P.Eng.
Principal, Specialist, RDH Building Science Inc.
John Straube, P.Eng.
Principal, Senior Specialist, RDH Building Science Inc.
Disclosure. The paper was authored by RDH Building Science with financial support from Advanced Architectural Products. RDH states that where specific products or systems appear as examples, their inclusion does not constitute an endorsement or recommendation.
Where A2P systems fit
The paper’s recommendation for gaps at cladding attachment is to specify a combined clip and insulation system rather than cutting board around hardware in the field. SMARTci® is built on that approach, with custom-profiled insulation panels that mate to the GreenGirt CMH™ Z-girt so the fit around the attachment is manufactured rather than cut on site. Read how thermal bypass happens and how to eliminate it.
Download the full white paper
19 pages, including the full reference list and the figures behind each finding.
Related reading
Thermal Bypass: What It Is, Why It Quietly Wastes Energy, and the One System That Guarantees It Is Eliminated
How gaps, cracks, and unintended air movement undercut a wall’s modeled R-value, and what it takes to eliminate them on a real project.
What Is Thermal Bridging? Causes and How to Eliminate It
How gaps, cracks, and unintended air movement undercut a wall’s modeled R-value, and what it takes to eliminate them on a real project.